Rhino Steel Industries logo

Coated Steel And Aluminium Coil Solutions

RhinoGuard aluminium-zinc alloy-coated coils and RhinoShield pre-painted steel and aluminium coils manufactured in the UAE. Compare substrate choices, exact product specifications, protective finishes and application requirements across the UAE and wider Middle East.

RhinoGuard And RhinoShield Product Range

Rhino Steel Industries brings together two specialist UAE operations: RhinoGuard Aluzinc coated steel coils manufactured in Umm Al Quwain, and RhinoShield pre-painted metal coils produced in Dubai Industrial City. Compare the substrate, coating and finished coil dimensions below before discussing a requirement with the relevant team.

Metallic Aluzinc coated steel coils in the RhinoGuard product range
RhinoGuard product brand logo

RhinoGuard Aluzinc Coated Steel Coils

Grade
Commercial Quality (LFQ/CQ/CS) / Structural Quality (SS)
Thickness
0.18 mm to 1.20 mm
Al-Zinc Coating
AZM20 | AZM30 | AZM70 | AZM100 | AZM150
Width
750 mm to 1250 mm
Slit Coils
Widths below 750 mm are slit coils
Coil Weight
Up to 15 MT
Coil ID
508 mm to 762 mm
Explore RhinoGuard
Silver pre-painted galvanized steel strip passing through the coating line
RhinoShield product brand logo

RhinoShield Pre-Painted Galvanized Steel Coils

Grade
Commercial Quality (LFQ/CQ/CS) / Structural Quality (SS)
Thickness
0.20 mm to 1.20 mm
Zinc Coating
G30 (90 gsm) | G40 (120 gsm) | G60 (180 gsm) | G90 (275 gsm)
Width
800 mm to 1250 mm
Slit Coils
Widths below 800 mm are slit coils
Coil Weight
Up to 6.00 MT
Coil ID
508 mm
Explore RhinoShield
Blue RhinoShield pre-painted Aluzinc coil
RhinoShield product brand logo

RhinoShield Pre-Painted Aluzinc Coils

Grade
Commercial Quality (LFQ/CQ/CS) / Structural Quality (SS)
Thickness
0.20 mm to 1.20 mm
Al-Zinc Coating
AZM70 | AZM100 | AZM150
Width
800 mm to 1250 mm
Slit Coils
Widths below 800 mm are slit coils
Coil Weight
Up to 6.00 MT
Coil ID
508 mm
Explore RhinoShield
Orange RhinoShield pre-painted aluminium coil
RhinoShield product brand logo

RhinoShield Pre-Painted Aluminium Coils

Alloy
AA3003 H46 | AA3004 H44 | AA3105 H46
Thickness
0.30 mm to 1.20 mm
Width
800 mm to 1250 mm
Slit Coils
Widths below 800 mm are slit coils
Coil Weight
Up to 3.00 MT
Coil ID
508 mm
Explore RhinoShield

Coated Metal Applications Across Industry

From a building envelope to a formed industrial component, the end use determines how a coated coil should be specified. Exposure, forming demands, surface appearance and compatibility with adjacent materials all matter. Explore the five applications below, then use the product and coating pages to develop the material specification.

Roofing And Cladding

Coated steel and aluminium coils are formed into roofing and cladding for industrial and commercial buildings. Metallic and paint coatings provide weather resistance and corrosion protection, while colour and finish choices support durable architectural envelopes. Select the substrate and coating system for the exposure, forming requirements and intended service conditions.

Discuss Material Suitability

Cold Storage Panels

Coated metal faces are used in insulated cold storage panels. The coating protects the metal surface in temperature-controlled environments and provides a finish suited to regular cleaning when correctly specified. Panel construction, insulation, joints and cleaning compatibility must be assessed together; suitability for hygiene-related requirements depends on the selected coating and intended use.

Discuss Material Suitability

Agricultural Structures

Coated steel products can be formed for agricultural buildings and related structures. Corrosion-resistant coatings help protect exposed metal in demanding service environments. Material selection should account for humidity, local exposure, cleaning practices and contact with agricultural chemicals to support durability.

Discuss Material Suitability

HVAC Systems

Coated metal products are used in suitable ventilation and HVAC components. Formability supports the production of ducts, casings and related profiles, while coating protection helps maintain the metal surface over time. Specify the substrate and finish for forming, condensation and the operating environment.

Discuss Material Suitability

Automotive Panels

Suitable coated metal products can support automotive panel applications requiring surface quality, formability and corrosion protection. Material, coating and forming requirements must be evaluated for the component and agreed with the customer before supply.

Discuss Material Suitability

Explore Manufacturing, Testing And Finishes

Technical selection is easier when the product data, manufacturing route and inspection requirements are considered together. These pages connect the finished coil specification to the process, finish options and quality controls behind it, helping customers prepare a clearer enquiry.

Compare technical specifications, coating choices, testing capabilities and applications using the dedicated pages.

Lab Facility

Understand the mechanical, surface and exposure-related equipment used to assess coated metal characteristics.

Explore laboratory testing

Long-Life Materials And Responsible Production

Responsible material use starts at the specification stage. Choosing a suitable coating, planning coil widths and protecting surfaces through fabrication can help avoid unnecessary losses. Durable finishes and the recyclability of the metal substrate are complementary considerations, rather than substitutes for careful use and maintenance.

Durability

Corrosion-resistant coatings support long service life and reduced replacement frequency.

Efficient Production

Continuous processing and monitoring aim to reduce waste and production variability.

Resource Stewardship

Manufacturing practices focus on responsible material and process use.

Quality As Sustainability

Reliable performance and consistent coatings reduce avoidable material losses.

Steel and aluminium are recyclable materials. Responsible specification, efficient use of coil widths and careful handling help limit avoidable material waste. Recycling at end of life depends on collection and appropriate processing; manufacturing efficiency and long service life remain practical priorities.

Choosing Coated Steel And Aluminium Coils

How do RhinoGuard and RhinoShield differ?

RhinoGuard is Aluzinc coated steel with a metallic aluminium-zinc alloy layer. RhinoShield is the pre-painted range, available on galvanized steel, Aluzinc steel and aluminium substrates. The appropriate choice depends on the application and required finish.

What information should a coil enquiry include?

Provide the product category, grade or alloy, thickness, width, coating designation, quantity, coil weight preference and delivery destination. For pre-painted material, add the colour reference, finish and intended use.

Can narrow widths be specified?

The listed standard widths are 800 mm to 1250 mm. Widths below 800 mm are slit coils. Discuss the required slit width and order details with the relevant facility.

Which coating is suitable for a particular project?

Consider the substrate, exposure, design detailing and fabrication method together. Use the published product and Colour Stack information to develop the brief, then confirm suitability and the final specification with the team.

Markets We Serve

Rhino Steel serves clients across the Middle East, Africa, Asia and Europe, supplying steel solutions for infrastructure, construction, energy and manufacturing.

Our global supply capability connects UAE manufacturing operations with customers in the countries below.

Middle East

  • United Arab Emirates (UAE)
  • Saudi Arabia (KSA)
  • Qatar
  • Oman
  • Bahrain
  • Kuwait

Africa

  • Djibouti
  • Ethiopia
  • Ghana
  • Guinea
  • Mauritania
  • Rwanda
  • Seychelles
  • Tanzania
  • Uganda
  • Zambia

Asia

  • Maldives
  • Sri Lanka
  • Thailand

Europe

  • Armenia
  • Georgia

Start With The Application Specify With Confidence

Tell us what you plan to manufacture and the substrate, dimensions, coating and quantity you need. We will direct the enquiry to the relevant facility.

Discuss Your Requirements